Cast-Resin Current Transformer

 
 
Unit price NegotiableCompare
Inquiry None
Views 0
Ship China after payment 3 Day In
Brand Acrel
Expired Valid long term
Update 2026-11-02 12:41
 
Contact
Follow0

Acrel Co., Ltd.

CorporateNo. 1 year
Information Not verified
Deposit Unpaid
  • China
  • Last login 11-02 10:38 •
  • Acrel (Mr.)  
Detailed description

● LQZJ4-0.66 (AKH-0.66/Q) metering current transformer

Function

The primary connection is direct type; the secondary current signal and primary voltage signal terminals are covered with a transparent terminal cover and lead-sealed to prevent electricity theft.

Applications

Energy metering circuits.

Ordering example

Specific model: LQZJ4-0.66/30 300A/5A

Technical requirements: rated current ratio 300A/5A; accuracy class 0.2S; rated burden 10VA.

Communication protocol: none

Auxiliary power supply: none

● LMZD-0.66 (AKH-0.66ZD) series metering current transformer

Function

This series is used together with billing energy meters of the power supply system. The product uses epoxy cast-resin insulation, and the secondary terminals are covered with a transparent cover and lead-sealed to prevent electricity theft. The accuracy classes are 0.2S and 0.5S, and the product fully complies with the State Grid Corporation enterprise standard Q/GDW572-2010.

Applications

Power supply system metering

Ordering example

Specific model: AKH-0.66/ZD1 200A/5A

Technical requirements: rated current ratio 200A/5A; accuracy class 0.2S; rated burden 10VA.

Communication protocol: none

Auxiliary power supply: none

● AKH-0.66/J series metering current transformer

Function

This series is used together with measuring instruments and other measurement and control devices. The product uses epoxy cast-resin insulation, and the secondary terminals are covered with a transparent cover and lead-sealed to prevent electricity theft. The accuracy class can reach 0.2S. The product is equivalent to LMZ-0.5 and LMZJ-0.66 and fully complies with national standard GB1206-2006, equivalent to IEC60044-1:2003.

Applications

Measurement and metering in low-voltage distribution systems

Ordering example

Specific model: AKH-0.66/J-30I 150A/5A

Technical requirements: rated current ratio 150A/5A; accuracy class 1; rated burden 2.5VA; 1 primary turn.

Communication protocol: none

Auxiliary power supply: none

● AKH-0.66/H series current transformer

Function

Large capacity with IP65 protection rating, suitable for low-voltage measurement on the transformer side. The protection class can reach 10P20, providing effective short-circuit or overload protection for motors. The square window allows busbar passage. Generally used with relay protection; can be used with the ARD3T motor protection unit and ALP line protection, and can also be used with ABB's SPAJ140C relay.

Applications

Transformer low-voltage measurement

Ordering example

Specific model: AKH-0.66/H-220×165 6000A/5A

Technical requirements: rated current ratio 6000A/5A; accuracy class 10P15; rated burden 30VA; 1 primary turn.

Communication protocol: none

Auxiliary power supply: none

Brand: Acrel (Jiangsu Acrel Electrical Manufacturing Co., Ltd.)

ReportFavorite 0Comment 0
More >Other products of this company
UL-Certified Current Transformer DJSF1352-D-800 Series DC Energy Meter ATE210 Series Composite Wireless Temperature Monitoring Sensor Closed-Loop Hall Voltage Sensor AHVS-L100 UL-Certified Current Transformer DJSF1352-D-800 Series DC Energy Meter ATE210 Series Composite Wireless Temperature Monitoring Sensor Closed-Loop Hall Voltage Sensor AHVS-L100