● LQZJ4-0.66 (AKH-0.66/Q) metering current transformer
Function
The primary connection is direct type; the secondary current signal and primary voltage signal terminals are covered with a transparent terminal cover and lead-sealed to prevent electricity theft.
Applications
Energy metering circuits.
Ordering example
Specific model: LQZJ4-0.66/30 300A/5A
Technical requirements: rated current ratio 300A/5A; accuracy class 0.2S; rated burden 10VA.
Communication protocol: none
Auxiliary power supply: none
● LMZD-0.66 (AKH-0.66ZD) series metering current transformer
Function
This series is used together with billing energy meters of the power supply system. The product uses epoxy cast-resin insulation, and the secondary terminals are covered with a transparent cover and lead-sealed to prevent electricity theft. The accuracy classes are 0.2S and 0.5S, and the product fully complies with the State Grid Corporation enterprise standard Q/GDW572-2010.
Applications
Power supply system metering
Ordering example
Specific model: AKH-0.66/ZD1 200A/5A
Technical requirements: rated current ratio 200A/5A; accuracy class 0.2S; rated burden 10VA.
Communication protocol: none
Auxiliary power supply: none
● AKH-0.66/J series metering current transformer
Function
This series is used together with measuring instruments and other measurement and control devices. The product uses epoxy cast-resin insulation, and the secondary terminals are covered with a transparent cover and lead-sealed to prevent electricity theft. The accuracy class can reach 0.2S. The product is equivalent to LMZ-0.5 and LMZJ-0.66 and fully complies with national standard GB1206-2006, equivalent to IEC60044-1:2003.
Applications
Measurement and metering in low-voltage distribution systems
Ordering example
Specific model: AKH-0.66/J-30I 150A/5A
Technical requirements: rated current ratio 150A/5A; accuracy class 1; rated burden 2.5VA; 1 primary turn.
Communication protocol: none
Auxiliary power supply: none
● AKH-0.66/H series current transformer
Function
Large capacity with IP65 protection rating, suitable for low-voltage measurement on the transformer side. The protection class can reach 10P20, providing effective short-circuit or overload protection for motors. The square window allows busbar passage. Generally used with relay protection; can be used with the ARD3T motor protection unit and ALP line protection, and can also be used with ABB's SPAJ140C relay.
Applications
Transformer low-voltage measurement
Ordering example
Specific model: AKH-0.66/H-220×165 6000A/5A
Technical requirements: rated current ratio 6000A/5A; accuracy class 10P15; rated burden 30VA; 1 primary turn.
Communication protocol: none
Auxiliary power supply: none
Brand: Acrel (Jiangsu Acrel Electrical Manufacturing Co., Ltd.)